The envirnomental tests are performed according to standards listed below or procedures delivered by the Client in upgraded climatic chamber Filka Feutron.
The temperature range -70 to +90 C deg., the humidity range 25%-95%.
The climatic chamber dimensions (capacity): 720mm x 700mm x 950mm.




Tested objects / Group of objects

Tested feature and test methods

Standards and/or documented test procedures

Electrotechnical materials and products (samples - elements extracted from the part), insulation covers

Environmental testing. Test methods. Tests. Test Z/AD:composite temperature/humidity cyclic test Temp.: (+25 +/- 2) C or (+652) C w.w. (93 +/- 3)%; (-10 +/- 2) C

PN-EN 60068-2-38:2010

Environmental testing. Test methods. Test Cab. Damp heat, steady state. Test Ca Temp.: (+40 +/- 2) C, w.w. (93+2)%-3%, Test Cb - Temp.: (+3040 +/- 2) C w.w. (8593 +/- 3)%, Test Db - Temp.: (+2555 +/- 3) C w.w. at least 95%

PN-EN 60068-2-78:2007
PN-EN 60068-2-30:2008
PN-EN 60684-2:2001 p. 21 i p. 22

Environmental testing. Test B. Dry heat. Test B Temp.: +30, +200 C

PN-EN 60068-2-2:2009

Environmental testing. Test methods. Test N. Change of temperature. Tests Na, Nb, Temp.: (-65 +200) C
Cold resistance
Test A
Temp.: (-65 +5) C

PN-EN 60068-2-33:2002
PN-EN 60068-2-14:2009
PN-EN 60068-2-1:2009

Products

Environmental testing. Test methods. Test Ec. Drop and topple, primarily for equipment-type specimens.

PN-EN 60068-2-31:2010